Glas

Salt Bath Furnaces for Chemical Hardening of Glass, Electrically Heated or Gas-Fired
 PRODUCT IMAGE PRODUCT IMAGE
 TS 40/30, electrically heated TSB 30/30, gas-fired
PRODUCT IMAGE

TS 30/18 with preheating chamber above the salt bath and crane to dip the charge in

TS 20/15 - TSB 90/80

Chemical hardening is mostly applied for the solidification of thin glasses with a thickness of up to 3 mm. Chemical pretensioning is recommended because the surface flatness can be maintained. Producers of copy machines, solar modules, microwave devices, measuring instruments as well as companies in the lighting industry, the automotive industry and other users of flat glass need to apply the toughest possible glass in their products. Nearly all glasses containing a large percentage of sodium can be strengthened by means of ion exchange.

  • Tmax 750  °C or 1000  °C in the salt bath
  • Safety technology according to EN 60519-2
  • Useful for heat treatment of steel
  • Bath temperature control
  • Electric (TS) all-round heating or gas heating (TSB)
  • Removable collar plate made of solid steel
  • Insulated swing-a-way lid
  • Temperature uniformity up to ∆T 4 K according to DIN 17052-1 in the bath
  • Over-temperature limiter in the furnace chamber to prevent dangerous conditions for the furnace or personnel
  • Bath control of salt bath and furnace chamber

Crucibles

  • Type P: low carbon steel, CrNi plated and corundum coated for carburizing baths up to 950  °C, neutral salt and annealing baths up to 850  °C
  • Type C: high alloy CrNi steel for neutral salt and annealing baths up to 1000  °C and for dip brazing of Aluminium

Additional equipment

  • Exhaust gas collection at rim for connection to an exhaust system
  • Custom dimensions
  • Enhanced safety systems for heat treatment of aluminium and magnesium in the salt bath with second over-temperature limiter and PLC-bath control with thermocouples in the salt bath and in the furnace chamber
ModelTmaxInner dimensions crucibleVolumeOuter dimensions in mmConnectedElectricalWeight
 °C²Ø in mmh in mmin lWDHload kW¹connection*in kg¹
TS 20/1575023050020850970800173-phase650
TS 30/18750300500309501070800203-phase700
TS 40/307504005006010501170800333-phase750
TS 50/4875050060011011501270970533-phase1000
TS 60/63750610800220125013701170703-phase1200
TS 70/727507001000370135014701370803-phase1500
TS 90/8075090010005001600170014001003-phase1700
           
TS, TSB 20/20100023050020850970800223-phase650
TS, TSB 30/301000300500309501070800333-phase700
TS, TSB 40/4010004005006010501170800443-phase750
TS, TSB 50/60100050060011011501270970663-phase1000
TS, TSB 60/721000610800220125013701170803-phase1200
TS, TSB 70/90100070010003701350147013701003-phase1500
TS, TSB 90/80100090010005001600170014001203-phase1700
¹Only for electric version *Please see page 61 for more information about supply voltage ²Salt bath temperature

Beställ informationer

Utskriftsversion